A existing customers of mine Gloria and Gil from Erith got in touch as after many electrical jobs, I highly recommended a new consumer unit as they had a old mantel board which consisted of circuit breakers, but they had a fault with the lighting circuit keep tripping constantly and not resetting.
After carrying out a EICR ( Electrical Installation Condition Report ) on their property, finding no issues, then my suggestion was to remove the board but the area I had to work with was very small for a normal board, so measured up and installed a small board with RCBOs, and see what could happen.
Once installed the sockets RCBO tripped out, after unplugging different electrical items, it turned out to be extension leads plugged in and removed these and the RCBO remained on but the lights still the same, once investigated it appeared the wiring in the loft for the light in the kitchen was wired up incorrectly and could not remove cable as it was a working station with boarding.
After careful consideration, I advise the customers that the earth was remove from the earth terminal in the board and a connector block on it, and all seven metal switches removed in case of electric shocks and replaced with plastic switches for safety.
Tested and certification with notification to building control.